{"id":364,"date":"2018-10-12T08:54:52","date_gmt":"2018-10-12T06:54:52","guid":{"rendered":"http:\/\/neuronetix.de\/?p=364"},"modified":"2018-10-12T09:02:34","modified_gmt":"2018-10-12T07:02:34","slug":"hpe-smart-array-cli-commands-on-esxi","status":"publish","type":"post","link":"https:\/\/neuronetix.de\/?p=364","title":{"rendered":"HPE Smart Array CLI commands on ESXi"},"content":{"rendered":"<p>Ich habe diesen genialen Artikel auf\u00a0<a href=\"https:\/\/kallesplayground.wordpress.com\" target=\"_blank\" rel=\"noopener\">Kalle\u00b4s Playground<\/a>\u00a0gefunden!<\/p>\n<pre><strong>Show configuration<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl all show config\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl all show config<\/pre>\n<pre><strong>Controller status<\/strong>\r\nESXi 5.5 -&gt;\u00a0\/opt\/hp\/hpssacli\/bin\/hpssacli ctrl all show status\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl all show status<\/pre>\n<pre><strong>Show detailed controller information for all controllers<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl all show detail\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl all show detail<\/pre>\n<pre><strong>Show detailed controller information for controller in slot 0<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 show detail\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 show detail<\/pre>\n<pre><strong>Rescan for New Devices<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli rescan\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli rescan<\/pre>\n<pre><strong>Physical disk status<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 pd all show status\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 pd all show status<\/pre>\n<pre><strong>Show detailed physical disk information<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 pd all show detail\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 pd all show detail<\/pre>\n<pre><strong>Logical\u00a0disk status<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 ld all show status\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 ld all show status<\/pre>\n<pre><strong>View Detailed Logical Drive Status<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 ld 2 show\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 ld 2 show<\/pre>\n<pre><strong>Create New RAID 0 Logical Drive<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0<\/pre>\n<pre><strong>Create New RAID 1 Logical Drive<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1<\/pre>\n<pre><strong>Create New RAID 5 Logical Drive<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5<\/pre>\n<pre><strong>Delete Logical Drive<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 ld 2 delete\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 ld 2 delete<\/pre>\n<pre><strong>Add New Physical Drive to Logical Volume<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7<\/pre>\n<pre><strong>Add Spare Disks<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7<\/pre>\n<pre><strong>Enable Drive Write Cache<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 modify dwc=enable\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 modify dwc=enable<\/pre>\n<pre><strong>Disable Drive Write Cache<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 modify dwc=disable\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 modify dwc=disable<\/pre>\n<pre><strong>Erase Physical Drive<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 pd 2I:1:6 modify erase\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 pd 2I:1:6 modify erase<\/pre>\n<pre><strong>Turn on Blink Physical Disk LED<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 ld 2 modify led=on\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 ld 2 modify led=on<\/pre>\n<pre><strong>Turn off Blink Physical Disk LED<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 ld 2 modify led=off\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 ld 2 modify led=off<\/pre>\n<pre><strong>Modify smart array cache read and write ratio (cacheratio=readratio\/writeratio)<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 modify cacheratio=100\/0\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 modify cacheratio=100\/0<\/pre>\n<pre><strong>Enable smart array write cache when no battery is present (No-Battery Write Cache option)<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 modify nbwc=enable\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 modify nbwc=enable<\/pre>\n<pre><strong>Disable smart array cache for certain\u00a0Logical Volume<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable<\/pre>\n<pre><strong>Enable\u00a0smart array cache for certain\u00a0Logical Volume<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable<\/pre>\n<pre><strong>Enable SSD Smart Path<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 array a modify ssdsmartpath=enable\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 array a modify ssdsmartpath=enable<\/pre>\n<pre><strong>Disable\u00a0SSD Smart Path<\/strong>\r\nESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl slot=0 array a modify ssdsmartpath=disable\r\nESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl slot=0 array a modify ssdsmartpath=disable<\/pre>\n<p>via <a href=\"https:\/\/kallesplayground.wordpress.com\/useful-stuff\/hp-smart-array-cli-commands-under-esxi\/\">HPE Smart Array CLI commands on ESXi<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Ich habe diesen genialen Artikel auf\u00a0Kalle\u00b4s Playground\u00a0gefunden! Show configuration ESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl all show config ESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl all show config Controller status ESXi 5.5 -&gt;\u00a0\/opt\/hp\/hpssacli\/bin\/hpssacli ctrl all show status ESXi 6.5 -&gt; \/opt\/smartstorageadmin\/ssacli\/bin\/ssacli ctrl all show status Show detailed controller information for all controllers ESXi 5.5 -&gt; \/opt\/hp\/hpssacli\/bin\/hpssacli ctrl all [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[10,43],"tags":[],"_links":{"self":[{"href":"https:\/\/neuronetix.de\/index.php?rest_route=\/wp\/v2\/posts\/364"}],"collection":[{"href":"https:\/\/neuronetix.de\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/neuronetix.de\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/neuronetix.de\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/neuronetix.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=364"}],"version-history":[{"count":2,"href":"https:\/\/neuronetix.de\/index.php?rest_route=\/wp\/v2\/posts\/364\/revisions"}],"predecessor-version":[{"id":367,"href":"https:\/\/neuronetix.de\/index.php?rest_route=\/wp\/v2\/posts\/364\/revisions\/367"}],"wp:attachment":[{"href":"https:\/\/neuronetix.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=364"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/neuronetix.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=364"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/neuronetix.de\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=364"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}